New from EchoServ: The MPE/iX 7.5 Year-2028 Date-Fix Patch & ECHO3000 RC 1.1 are ready for download. MPE/iX 7.5 Date-Fix Patch ↓ Install Guide & 60-Day Demo ↓
Allegro Consultants

HP 3000 & HP-UX Specialists · Since 1984

Dependable care for classic HP 3000 systems — in your computer room or on your desk.

For four decades, Allegro Consultants and EchoServ have kept mission-critical MPE/iX and HP-UX environments running smoothly. Whether you run production HP 3000 iron today or want a classic colon prompt at home, you are in good company here.

ECHO3000 Virtual HP 3000 · Hobbyist Edition Release Candidate 1.1
ECHO3000 for Windows 10 / 11
ECHO3000 for Linux x86-64
Classic 1980s HP 3000 computer room with two-tone cream and brown minicomputer cabinets, upright 9-track open-reel magnetic tape drive, and operator console terminal.
Classic HP 3000 Computer Room MPE · MPE/iX 7.5 · Non-Stop Support

MPE/iX 7.5 Patch Download · C.75.SE Release B1

The Year-2028 Date-Fix Patch for MPE/iX 7.5

Stock MPE/iX 7.5 (C.75.00) treats dates after December 31, 2027 as 19xx dates or rejects them outright (CIERR 11711). EchoServ's Date-Fix patch updates your own MPE/iX 7.5 system libraries and utilities in place through December 31, 2077 — without replacing your discs, without redistributing HP operating-system binaries, and without requiring the POSIX shell.

Calendar Window: 1950 – 2077 Check-First Preflight (JDFXPF) 17 System Files + STM diagmond 60-Day Full Evaluation Included
Classic upright 9-track magnetic tape drive beside an HP 3000 bay, tape canisters, and green-bar console binder.
Install via HP Stage/iX or CSLT Tape 1950 – 2077
Option 1 · Recommended by EchoServ

Stage/iX Package (Disk / FTP Install)

Recommended for almost all MPE/iX 7.5 customers with FTP access. Hewlett-Packard did a great job designing Stage/iX — upload kit_b1.std (1.4 MB) to disk and stage cleanly with zero physical tapes.

  • No tapes or SYSGEN cuts: Restores directly from disk (;DEV=DISC), builds & verifies in DFXW.SYS, and stages into uncommitted DFXPATCH with a single reboot.
  • One-command rollback: Unpatched BASE stays preserved in /SYS/hpstage/base_archive/ — switch back anytime with STAGEMAN> SET BASE.
Option 2 · Traditional CSLT & Tape

Tape Customer Package (CSLT + Physical / Virtual Tape)

For shops whose OS change-control policy requires cutting traditional System Load Tapes (SYSGEN CSLT + ISL> UPDATE), physical DDS/DAT/DLT/9-track drives, or SIMH/QEMU .tap virtual drives.

  • Includes both formats: kit_b1.std (for ;DEV=DISC or TAPECOPY;INFO="DT" to physical tape) and kit_b1.tap (for emulated tape drives).
  • Verified back-out & install reels: Cuts and CHECKSLT-verifies an unpatched Back-Out CSLT (JDFXBAK) before building your Patched CSLT (JDFXCUT).

How the 60-Day Demo Works — and What Happens After 60 Days

During the 60-Day Evaluation

Your first patched boot automatically starts a 60-day full-featured evaluation window. Every Year-2028 fix across the kernel, file system, batch scheduler, backup tools, databases, and Native Mode COBOL & RPG runs unrestricted, and each logon displays the remaining days (DEMO MODE: 60 day(s) remaining). Existing permanent licenses are preserved via ;KEEP.

After 60 Days (Safe, Non-Destructive Fallback)

If 60 days pass without a permanent license, your HP 3000 never halts, never locks out users, and never damages stored file dates on disc (file-close label protection remains active). Date displays safely clamp or revert (:SHOWTIME and file labels clamp to 2027, Native FMTCALENDAR reverts to stock 19xx, and HPDATECONVERT code 14 returns a clean range error for 2028+ inputs). Installing DFXLICEN.PUB.SYS restores full 2028–2077 operation immediately, or you can switch back to unpatched BASE.

Running the ECHO3000 Hobbyist Emulator? Nothing to install — RC 1.1 already carries the Date Fix pre-staged and permanently licensed for the default emulator.

Hardware for Real Iron · MPE/iX & HP-UX

When the tape drive dies, the HP 3000 shouldn't.

Devices on Demand plugs straight into your SCSI port and emulates HP-supported tape and disc drives — C1537A DDS, DLT7000, DLT8000, and LTO — holding hundreds of virtual reels on a single SD card.

  • Every classic HP tape drive in one small unit. Works natively with MPE/iX STORE/RESTORE, System Load Tapes, and HP-UX fbackup/frecover.
  • A whole tape library on an SD card. Every virtual reel is a standard file you can copy, archive off-site, or mount in ECHO3000.
  • Bus-powered, no wall wart. Draws power cleanly from the SCSI connection — nothing extra to wire into the rack.
  • Verified against HP's own drivers. Built so your HP 3000 or HP 9000 sees a genuine Hewlett-Packard peripheral.
Devices on Demand FW-SCSI unit connected to an HP SCSI cable with SD card slot.
Devices on Demand · FW-SCSIBus-Powered · SD Card Media

Commercial Support & Consulting

Practical engineering support for the systems your business still counts on.

Responsive, experienced help for HP 3000 MPE/iX and HP-UX shops — from everyday administration and performance tuning to crash recovery, hardware transitions, and custom patching.

Row of beige Hewlett-Packard HP 3000 Series 959KS corporate business system cabinets and peripheral racks in a data center.
HP 3000 Series 900 & A/N-ClassProduction Support

Software Support

OS help desk & break/fix

Direct access to engineers who know MPE/iX and HP-UX inside and out — kernel dumps, subsystem patches, networking, and compiler toolchains.

MPE/iXHP-UXEloquenceGCCLinux

Managed Services

Steady hands at the console

Scheduled backups, spool and disc housekeeping, security reviews, and proactive monitoring so retiring staff never leave your system unattended.

MonitoringSTORE BackupsStage/iX Patching

Recovery & Migration

On your schedule, never forced

Recover data from aging drives or tapes, stand up virtualized standby systems, or move TurboIMAGE data cleanly to SQL when you choose.

Data RecoveryTurboIMAGE → SQLVirtual Standby

Allegro Software

Proven HP 3000 utilities

The classic Allegro software line for online disc defragmentation, database export, and performance diagnostics that HP 3000 managers trust.

De-Frag/XHourGlassDBCSVDiskPerf

Stewardship & Continuity

Allegro's next chapter.

Since 1984, Allegro Consultants has stood beside organizations running mission-critical HP 3000/MPE/iX and HP-UX systems long after Hewlett-Packard stepped back.

As Donna Hofmeister enjoys a well-earned retirement, Allegro's support operations, software utilities, and customer commitments continue uninterrupted under the stewardship of Craig Lalley and EchoServ, LLC.

— Craig Lalley, EchoServ, LLC

  • Your contractsContinue seamlessly — no re-signing and zero gaps in support coverage.
  • Your systemsSupported by engineers with deep, source-level MPE/iX and PA-RISC experience.
  • Your horizonLong-term. With the Year-2028 Date Fix and ECHO3000, your calendar runs through 2077.
40+ yrs
HP 3000 & HP-UX heritage
2077
MPE/iX Date-Fix horizon
24/7
Support availability
0
Forced migrations