MPE/iX 7.5 (C.75.00) · Calendar Window 1950–2077
Year-2028 Date-Fix Patch: Simple Install Guide & 60-Day Demo
Stock MPE/iX 7.5 rolls back into 19xx or rejects dates with CIERR 11711 once the clock passes December 31, 2027. EchoServ's Release B1 patch updates your own MPE/iX 7.5 libraries and utilities in place — with a read-only check-first preflight (JDFXPF), zero HP OS binary redistribution, zero POSIX shell requirement, and a safe 60-day evaluation window.
Choose one package
Install by one route only (Stage/iX or CSLT Tape — never both). Both zips include complete step-by-step guides and printable 78-column console checklists.
1. Stage/iX Package
Ideal for any MPE/iX 7.5 system with FTP access. Hewlett-Packard did a great job designing Stage/iX — binary-FTP kit_b1.std (1.4 MB) to disk, build & verify in DFXW.SYS, stage into uncommitted DFXPATCH, and reboot once. Zero physical tapes, zero SYSGEN, and one-command rollback (STAGEMAN> SET BASE).
2. Tape Customer Package
For sites whose OS maintenance policy standardizes on System Load Tapes (SYSGEN CSLT + CHECKSLT + ISL> UPDATE), physical DDS/DAT/DLT/9-track drives, or SIMH/QEMU virtual .tap drives. Includes both kit_b1.std (for real hardware) and kit_b1.tap (for emulators).
DFXPATCH and permanently licensed for the default emulator configuration.
The 60-Day Demo & What Happens After 60 Days
Plain-spoken answers on how the evaluation behaves on production and test HP 3000 systems.
1. Conditions During the 60-Day Demo
- Starts automatically on first patched boot: When your patched MPE/iX 7.5 system boots without a machine-matched permanent
DFXLICEN.PUB.SYS, it automatically enters a 60-day evaluation window. - 100% full-featured: Every Year-2028 fix across all 17 system files (
1950-01-01through2077-12-31) is completely active — nothing is crippled or held back during evaluation. - Clear logon countdown: Each logon prints a one-line reminder so there are never surprises:
EchoServ MPE/iX Year-2028 Date Fix - DEMO MODE: 60 day(s) remaining. Contact EchoServ for a license file to continue after the demo.
- Existing licenses & demo counters respected: Restoring with
;KEEPensures an existing permanentDFXLICEN.PUB.SYSis never overwritten, and re-running a kit restore does not reset an active evaluation counter. (If you already had a permanent license and later swap a network card or CPU board so hardware binding mismatches, MPE transitions cleanly into a fresh 60-day evaluation window rather than halting.)
2. Exactly What Happens After 60 Days (If No License Is Installed)
If the 60-day evaluation reaches zero without a valid DFXLICEN.PUB.SYS installed:
- Normal OS availability continues: Your HP 3000 continues booting, accepting user logons, and running batch jobs and applications without interruption.
- Stored file dates on disc remain protected: File-close label write-back protection and
ALTSECsafeguards stay active even after demo expiry, so files carrying2028+timestamps on disc are never damaged. - Date displays & conversions clamp or revert safely:
:SHOWTIME,:SHOWCLOCK, and file-label date displays clamp at2027.- Native Mode
FMTCALENDARreverts to stock MPE/iX19xxformatting (Compatibility ModeFMTCALENDARcontinues displaying2028+, andSTORE ;STOREDIRdirectory names retain trueYYYYMMDDdates with a shifted 3-letter weekday suffix). HPDATECONVERTinto datecode14returns an explicit range error for2028+inputs rather than silently returning a wrong2027value.
- Instant recovery with one file (no reinstall, no reboot): Dropping a permanent
DFXLICEN.PUB.SYSonto your system immediately restores full2028–2077operation — you do not have to re-stage, re-link, or cut tapes again. - Or clean back-out to unpatched
BASE: With your system clock at the current date (<= 2027), you can switch back to stock MPE/iX 7.5 anytime viaSTAGEMAN> SET BASE(Stage/iX) orJDFXFNB+ your Back-OutCSLT(Tape).
Simple Stage/iX Instructions
Summary of INSTALL-STAGEIX.md and CONSOLE_STAGEIX.txt inside the Stage/iX zip. Always read the full guide in the zip before starting your maintenance window.
Upload kit_b1.std to KIT.PUB.SYS
Complete a verified full system backup first, log on at the console as MANAGER.SYS,PUB, confirm STAGEMAN STATUS shows BASE, and binary-FTP kit_b1.std from your PC:
ftp <your-hp3000-host> Name: MANAGER.SYS ftp> binary ftp> put kit_b1.std KIT.PUB.SYS;REC=-256,1,F,BINARY;CODE=2501;DISC=20000 ftp> quit
Note: Systems with B5152AA Store-to-Disk restore straight from KIT.PUB.SYS using ;DEV=DISC. If Store-to-Disk is not enabled on your license, INSTALL-STAGEIX.md includes a 4-line TAPECOPY.PUB.SYS;INFO="DT" fallback to write KIT.PUB.SYS onto a tape on LDEV 7.
Create DFXW.SYS and stream JDFXPF
Restore only the 4 read-only preflight files and run JDFXPF. It checks LDEV 1 permanent free space (~630,000 sectors typical) and verifies every one of the 17 target system files matches a supported MPE/iX 7.5 level before installing a single module:
:NEWGROUP DFXW;CAP=IA,BA,PH,PM,MR,DS :FILE T=KIT.PUB.SYS;DEV=DISC :RESTORE *T;DFXAPPLY.DFXW.SYS,DFXTABLE.DFXW.SYS,PFSCAN0.DFXW.SYS,JDFXPF.DFXW.SYS;SHOW :RESET T :STREAM JDFXPF.DFXW.SYS
Check the job's spool file (:LISTSPF @ → :PRINT O<nnn>.OUT.HPSPOOL;PAGE=0):
- GREEN:
JDFXPF ROUTE-B TOOL STAGEMAN PRESENTandJDFXPF ALL FIT - GO ON TO STEP 10→ proceed to Step 3. - RED:
JDFXPF DOES NOT FIT - STOP→ nothing was installed; email the spool output to craig@allegrosupport.com.
DFXW.SYS
Stream JDFXLNK, JDFXAPP, and JDFXSTA
Restore the 39 work files into DFXW.SYS and the 3 license/demo anchor files with ;KEEP, then stream the three build jobs one after another while your live operating system remains completely untouched:
:FILE T=KIT.PUB.SYS;DEV=DISC :RESTORE *T;@.DFXW.SYS;SHOW :RESET T :FILE T=KIT.PUB.SYS;DEV=DISC :RESTORE *T;DFXLICEN.PUB.SYS,/opt/.clkfmt,/SYS/.offset;KEEP;SHOW;CREATE=PATH :RESET T :STREAM JDFXLNK.DFXW.SYS :STREAM JDFXAPP.DFXW.SYS :STREAM JDFXSTA.DFXW.SYS
Confirm each spool file ends with JDFXLNK COMPLETE, JDFXAPP COMPLETE - ALL 16 COPIES BUILT AND VERIFIED, and JDFXSTA COMPLETE - BUILT, NOT STAGED.
DFXPATCH, Reboot Once & Verify
Activate with STAGEMAN and stream JDFXVER
Save DBRECOV0.PUB.SYS, stage the 17 verified files into uncommitted DFXPATCH via STAGEMAN (SF DFXPATCH, ... ;MOVE, COMPLETE DFXPATCH, VALIDATE DFXPATCH, SET DFXPATCH — exact commands in CONSOLE_STAGEIX.txt), shut down cleanly, boot ISL> START NORECOVERY, and run live verification:
:STREAM JDFXVER.DFXW.SYS
Confirm VERIFY ALL OK 15 and SECCHK 17 OF 17 OK, then complete the short interactive SOMPATCH step for Support Tools Manager diagmond in Section 8 of INSTALL-STAGEIX.md.
Switching back to unpatched BASE anytime
Do not run STAGEMAN> COMMIT so your unpatched BASE archive stays available. With the system clock <= 2027, you can revert online or at ISL> in one command:
:STAGEMAN STAGEMAN> SET BASE STAGEMAN> STATUS STAGEMAN> EXIT -- or offline at the console ISL> prompt: -- ISL> STAGEISL STAGEISL> SET STAGE=BASE STAGEISL> EXIT
Simple Tape (CSLT) Instructions
Summary of INSTALL-TAPE.md and CONSOLE_TAPE_FULL.txt inside the Tape zip. Have 2 blank write-enabled system tapes ready (Back-Out CSLT & Patched CSLT).
kit_b1.std (Real Hardware) vs. kit_b1.tap (Emulators)
- Real HP 3000 Hardware → use
kit_b1.std: Binary-FTPkit_b1.stdtoKIT.PUB.SYS;REC=-256,1,F,BINARY;CODE=2501;DISC=20000. IfB5152AAStore-to-Disk is installed, restore directly with:FILE T=KIT.PUB.SYS;DEV=DISC(saving a third tape) while still cutting physicalCSLTreels! Otherwise, writeKIT.PUB.SYSonto a physical kit tape onLDEV 7using freewareTAPECOPY.PUB.SYS;INFO="DT"(never passkit_b1.taptoTAPECOPY) and write-protect that reel. - Virtual Tape Drives (SIMH / QEMU / Devices on Demand) → use
kit_b1.tap: Mountkit_b1.tapread-only onLDEV 7.
Run JDFXPF first, then restore @.DFXW.SYS
After a verified full system backup, create DFXW.SYS, restore the 4 preflight files from *T, and stream JDFXPF.DFXW.SYS. Proceed only on JDFXPF ALL FIT - GO ON TO STEP 10, then restore @.DFXW.SYS (39 files) and DFXLICEN.PUB.SYS,/opt/.clkfmt,/SYS/.offset;KEEP;SHOW;CREATE=PATH. (If your tape drive is not LDEV 7, edit !SETVAR TAPELDEV in JDFXBAK and JDFXCUT.)
Cut JDFXBAK and verify at CHECKSLT level 2
Mount Blank Tape #1 write-enabled, cut a complete unpatched System Load Tape of your live system, and verify it before building anything:
:STREAM JDFXBAK.DFXW.SYS :PRINT SGOUTBAK.DFXW.SYS;PAGE=0 :CHECKSLT.MPEXL.TELESUP (enter level 2 → confirm 0 errors across all 3 file groups)
Remove, label, and write-protect your Back-Out CSLT tape.
Stream JDFXLNK / JDFXAPP / JDFXSTA, then cut JDFXCUT
Stream JDFXLNK, JDFXAPP, and JDFXSTA sequentially in DFXW.SYS. Then mount Blank Tape #2 write-enabled and cut your Patched CSLT (HOLD + TAPE MODE=NOCHANGE leaves your on-disc SYSGEN configuration untouched):
:STREAM JDFXCUT.DFXW.SYS :PRINT SGOUTCUT.DFXW.SYS;PAGE=0 :CHECKSLT.MPEXL.TELESUP (enter level 2 → confirm 0 errors across all 3 file groups)
Remove, label, and write-protect your Patched CSLT tape.
ISL> UPDATE, Two Disc Boots & JDFXFIN
Install the 10 core SLT files + 7 standalone utilities
- Shut down cleanly (
STMSHUT,NSCONTROL STOP,NETCONTROL STOP,SHUTDOWN SYSTEM), boot from the write-protected Patched CSLT tape (Interact with IPL? Y), and enterISL> UPDATE. - Complete the standard two-boot disc startup: After
END of LOAD(update)., boot from your primary disc (ISL> START NORECOVERY). The first boot runsSYSSTARTUPDATEprocessing withLIMIT 1,1(CIERR 80) — do not log on; pressCtrl-A, enter=SHUTDOWN, and bootISL> START NORECOVERYa second time. - Log on as
MANAGER.SYS,PUBand stream:STREAM JDFXFIN.DFXW.SYSto install the 7 standalone utilities and verify all 17 live files (VERIFY ALL OK 15+SECCHK 17 OF 17 OK), then apply the interactivediagmondstep inINSTALL-TAPE.md§9.
Tape Back-Out: With clock <= 2027, stream :STREAM JDFXFNB.DFXW.SYS (restores the 7 stock utilities), shut down cleanly, and boot your verified Step 3 Back-Out CSLT for ISL> UPDATE + two disc boots.
Ordering a Permanent License
One small ASCII file (DFXLICEN.PUB.SYS) unlocks your machine through 2077.
Send Two Quick Status Outputs to EchoServ
Log on as MANAGER.SYS, run these two read-only commands, and email the output to craig@allegrosupport.com:
:SHOWVAR HPCPUNAME,HPSUSAN :LINKCONTROL @;STATUS=CONFIGURATION
- Bound to Factory
Default Station Address: Permanent licenses validateHPSUSAN,HPCPUNAME, and yourPCI 100BTadapter's factoryDefault Station Address— soNMMGRsoftware-overriddenCurrent Station Addresssettings (for SNA, DECnet, or failover) and custom link names continue to work seamlessly. (On legacy non-PCI 900-series DIO/NIO LAN adapters or systems with no configured LAN link, station-address matching is skipped automatically.) - Installing your license: Upload the returned file in ASCII mode as
DFXLICEN.PUB.SYS(REC=-80,,F,ASCII, no lockword). Full2028–2077operation is active immediately.
What Is Updated, Operator Notes & Checksums
Full details are in RELEASE-NOTES-DATEFIX.md inside both downloads.
The 17 Updated MPE/iX 7.5 Files (Plus STM diagmond)
- Core OS & Command Interpreter:
NL.PUB.SYS(16-bitCALENDARwindowing1950–2077, leap years2028..2076, file-label membrane, password aging, spoolerSELEQ, cleanSHUTDOWN SYSTEMpast2038),START.MPEXL.SYS,STAGEISL.MPEXL.SYS,SL.PUB.SYS(:STREAMscheduling across2028–2077, CMFMTCALENDAR/DATELINE/CONVERTDATE),CI.PUB.SYS,CATALOG.PUB.SYS, andVERSION.PUB.SYS(C.75.SE Special Edition 2026). - Commercial Languages & Shared Runtime (
XL.PUB.SYS): Native Mode COBOL II/XL (COB74XL&COB85XLACCEPT ... FROM DATE/DAY/DAY-OF-WEEKandCURRENT-DATE), Native Mode RPG/XL (UDATE,*YEAR,TIME), plus ALLBASE/SQL, HP Business BASIC/XL, and Transact/iX shared date intrinsics. - Backup, Databases, File Transfer & Diagnostics: PA-RISC 1.1
STORE.PUB.SYS&STORECAT.PUB.SYS, TurboIMAGE/XLDBSCHEMA.PUB.SYS&DBRECOV.PUB.SYS,QUERY.PUB.SYS,MSGUTIL.PUB.SYS,KSAMUTIL.PUB.SYS, ARPAFTP.ARPA.SYS&FTPSRVR.ARPA.SYS, and STM/usr/sbin/stm/uut/bin/sys/diagmond(post-2010 startup fix).
Good to Know Before Testing High Dates
- Hardware clock caution (
:SETCLOCK ...;NOW):SETCLOCK ;NOWwrites your HP 3000's non-volatile PDC hardware clock. Only run optional2028clock checks when no users or production jobs are active, never set production clocks at or past2038(POSIX 32-bittime_ttools remain subject to the2038-01-19epoch ceiling), and always restore the true current date and time right afterward. - Legacy Compatibility Mode COBOL (
COBOLIICODE=PROG): Native ModeCOB74XLandCOB85XLare fixed in Release B1. Legacy CMCOBOLIIprograms linked against CMCOBLIB.PUB.SYScompute dates from the raw 7-bit year; recompile withCOB74XL/COB85XLor call windowedDATELINE/FMTCALENDARdirectly (CMCOBLIBis scheduled for the next release). - ANSI tape expiration labels:
:FILE ...;LABEL=accepts expiration years through2049; avoid assigning2028+ANSIHDR1tape expiration dates in Release B1 (zero-expiry tapes work cleanly withSTOREandRESTORE).
Package & Kit Checksums
| File | Size | MD5 / SHA-256 |
|---|---|---|
| EchoServ-MPEiX75-DateFix-B1-StageiX.zip Recommended Stage/iX Web Package |
372,841 B (364.1 KB) |
MD5: f778a9efcbc17ee6229b25bc42f5d6e8SHA256: 86086fd42d88171d830ecd48fb5dfb0458100cb4ebe7e390681a450a2f718847 |
| EchoServ-MPEiX75-DateFix-B1-Tape.zip CSLT & Physical / Virtual Tape Package |
723,027 B (706.1 KB) |
MD5: 248e1f9e406e53d6a14467a75f71d8f9SHA256: 1d9dd1e2cc08f34bfdb7bb800f378e49a2b44742d60c7050173c45e632468830 |
| kit_b1.std (inside both zips, CODE=2501) | 1,427,456 B | MD5: 5544a1bacd97cbc1c1513fb5101edd95SHA256: abeb89d971b6fb4c7b1624520304707a8fa405135d7d08298568555f7dfb35fa |
| kit_b1.tap (inside Tape zip, SIMH .tap) | 1,427,456 B | MD5: 1c89288ff21f1a2a12e195cbff4e7750SHA256: 21e03dad8edbec4c9546ca5e0b1df73f8e885dd2892c7043df813612b3c700fc |