Allegro Consultants · EchoServ, LLC — MPE/iX 7.5 Year-2028 Date-Fix Patch (C.75.SE Release B1) ← Back to Home Page
Allegro Consultants

MPE/iX 7.5 (C.75.00) · Calendar Window 1950–2077

Year-2028 Date-Fix Patch: Simple Install Guide & 60-Day Demo

Stock MPE/iX 7.5 rolls back into 19xx or rejects dates with CIERR 11711 once the clock passes December 31, 2027. EchoServ's Release B1 patch updates your own MPE/iX 7.5 libraries and utilities in place — with a read-only check-first preflight (JDFXPF), zero HP OS binary redistribution, zero POSIX shell requirement, and a safe 60-day evaluation window.

Classic HP 3000 upright 9-track magnetic tape drive, canisters, and green-bar console binder.
Stage/iX Disk or CSLT TapeC.75.SE Release B1
Step 0 · Download

Choose one package

Install by one route only (Stage/iX or CSLT Tape — never both). Both zips include complete step-by-step guides and printable 78-column console checklists.

Recommended for Most Sites

1. Stage/iX Package

Ideal for any MPE/iX 7.5 system with FTP access. Hewlett-Packard did a great job designing Stage/iX — binary-FTP kit_b1.std (1.4 MB) to disk, build & verify in DFXW.SYS, stage into uncommitted DFXPATCH, and reboot once. Zero physical tapes, zero SYSGEN, and one-command rollback (STAGEMAN> SET BASE).

MD5: f778a9efcbc17ee6229b25bc42f5d6e8
SHA-256: 86086fd42d88171d830ecd48fb5dfb0458100cb4ebe7e390681a450a2f718847
CSLT + Physical or Virtual Tape

2. Tape Customer Package

For sites whose OS maintenance policy standardizes on System Load Tapes (SYSGEN CSLT + CHECKSLT + ISL> UPDATE), physical DDS/DAT/DLT/9-track drives, or SIMH/QEMU virtual .tap drives. Includes both kit_b1.std (for real hardware) and kit_b1.tap (for emulators).

MD5: 248e1f9e406e53d6a14467a75f71d8f9
SHA-256: 1d9dd1e2cc08f34bfdb7bb800f378e49a2b44742d60c7050173c45e632468830
Running the ECHO3000 Hobbyist Emulator? You do not need to download or install either patch kit — ECHO3000 RC 1.1 already ships with the Year-2028 Date Fix pre-installed in Stage/iX area DFXPATCH and permanently licensed for the default emulator configuration.
Demo Conditions

The 60-Day Demo & What Happens After 60 Days

Plain-spoken answers on how the evaluation behaves on production and test HP 3000 systems.

First Rule — Your System and Data Stay Safe: Whether you are inside the 60-day demo or past day 60 without a license, the patch never halts MPE/iX, never blocks logons or batch jobs, and never corrupts or overwrites stored 2028+ file dates on disc.

1. Conditions During the 60-Day Demo

  • Starts automatically on first patched boot: When your patched MPE/iX 7.5 system boots without a machine-matched permanent DFXLICEN.PUB.SYS, it automatically enters a 60-day evaluation window.
  • 100% full-featured: Every Year-2028 fix across all 17 system files (1950-01-01 through 2077-12-31) is completely active — nothing is crippled or held back during evaluation.
  • Clear logon countdown: Each logon prints a one-line reminder so there are never surprises:
    EchoServ MPE/iX Year-2028 Date Fix - DEMO MODE: 60 day(s) remaining.
    Contact EchoServ for a license file to continue after the demo.
  • Existing licenses & demo counters respected: Restoring with ;KEEP ensures an existing permanent DFXLICEN.PUB.SYS is never overwritten, and re-running a kit restore does not reset an active evaluation counter. (If you already had a permanent license and later swap a network card or CPU board so hardware binding mismatches, MPE transitions cleanly into a fresh 60-day evaluation window rather than halting.)

2. Exactly What Happens After 60 Days (If No License Is Installed)

If the 60-day evaluation reaches zero without a valid DFXLICEN.PUB.SYS installed:

  • Normal OS availability continues: Your HP 3000 continues booting, accepting user logons, and running batch jobs and applications without interruption.
  • Stored file dates on disc remain protected: File-close label write-back protection and ALTSEC safeguards stay active even after demo expiry, so files carrying 2028+ timestamps on disc are never damaged.
  • Date displays & conversions clamp or revert safely:
    • :SHOWTIME, :SHOWCLOCK, and file-label date displays clamp at 2027.
    • Native Mode FMTCALENDAR reverts to stock MPE/iX 19xx formatting (Compatibility Mode FMTCALENDAR continues displaying 2028+, and STORE ;STOREDIR directory names retain true YYYYMMDD dates with a shifted 3-letter weekday suffix).
    • HPDATECONVERT into datecode 14 returns an explicit range error for 2028+ inputs rather than silently returning a wrong 2027 value.
  • Instant recovery with one file (no reinstall, no reboot): Dropping a permanent DFXLICEN.PUB.SYS onto your system immediately restores full 2028–2077 operation — you do not have to re-stage, re-link, or cut tapes again.
  • Or clean back-out to unpatched BASE: With your system clock at the current date (<= 2027), you can switch back to stock MPE/iX 7.5 anytime via STAGEMAN> SET BASE (Stage/iX) or JDFXFNB + your Back-Out CSLT (Tape).
Option 1 · Recommended

Simple Stage/iX Instructions

Summary of INSTALL-STAGEIX.md and CONSOLE_STAGEIX.txt inside the Stage/iX zip. Always read the full guide in the zip before starting your maintenance window.

Step 1 · Backup & Upload via Binary FTP

Upload kit_b1.std to KIT.PUB.SYS

Complete a verified full system backup first, log on at the console as MANAGER.SYS,PUB, confirm STAGEMAN STATUS shows BASE, and binary-FTP kit_b1.std from your PC:

ftp <your-hp3000-host>
Name: MANAGER.SYS
ftp> binary
ftp> put kit_b1.std KIT.PUB.SYS;REC=-256,1,F,BINARY;CODE=2501;DISC=20000
ftp> quit

Note: Systems with B5152AA Store-to-Disk restore straight from KIT.PUB.SYS using ;DEV=DISC. If Store-to-Disk is not enabled on your license, INSTALL-STAGEIX.md includes a 4-line TAPECOPY.PUB.SYS;INFO="DT" fallback to write KIT.PUB.SYS onto a tape on LDEV 7.

Step 2 · Check-First All-or-Nothing Preflight

Create DFXW.SYS and stream JDFXPF

Restore only the 4 read-only preflight files and run JDFXPF. It checks LDEV 1 permanent free space (~630,000 sectors typical) and verifies every one of the 17 target system files matches a supported MPE/iX 7.5 level before installing a single module:

:NEWGROUP DFXW;CAP=IA,BA,PH,PM,MR,DS
:FILE T=KIT.PUB.SYS;DEV=DISC
:RESTORE *T;DFXAPPLY.DFXW.SYS,DFXTABLE.DFXW.SYS,PFSCAN0.DFXW.SYS,JDFXPF.DFXW.SYS;SHOW
:RESET T
:STREAM JDFXPF.DFXW.SYS

Check the job's spool file (:LISTSPF @ → :PRINT O<nnn>.OUT.HPSPOOL;PAGE=0):

  • GREEN: JDFXPF ROUTE-B TOOL STAGEMAN PRESENT and JDFXPF ALL FIT - GO ON TO STEP 10 → proceed to Step 3.
  • RED: JDFXPF DOES NOT FIT - STOP → nothing was installed; email the spool output to craig@allegrosupport.com.
Step 3 · Restore & Build Inside Scratch Group DFXW.SYS

Stream JDFXLNK, JDFXAPP, and JDFXSTA

Restore the 39 work files into DFXW.SYS and the 3 license/demo anchor files with ;KEEP, then stream the three build jobs one after another while your live operating system remains completely untouched:

:FILE T=KIT.PUB.SYS;DEV=DISC
:RESTORE *T;@.DFXW.SYS;SHOW
:RESET T
:FILE T=KIT.PUB.SYS;DEV=DISC
:RESTORE *T;DFXLICEN.PUB.SYS,/opt/.clkfmt,/SYS/.offset;KEEP;SHOW;CREATE=PATH
:RESET T
:STREAM JDFXLNK.DFXW.SYS
:STREAM JDFXAPP.DFXW.SYS
:STREAM JDFXSTA.DFXW.SYS

Confirm each spool file ends with JDFXLNK COMPLETE, JDFXAPP COMPLETE - ALL 16 COPIES BUILT AND VERIFIED, and JDFXSTA COMPLETE - BUILT, NOT STAGED.

Step 4 · Stage into Uncommitted DFXPATCH, Reboot Once & Verify

Activate with STAGEMAN and stream JDFXVER

Save DBRECOV0.PUB.SYS, stage the 17 verified files into uncommitted DFXPATCH via STAGEMAN (SF DFXPATCH, ... ;MOVE, COMPLETE DFXPATCH, VALIDATE DFXPATCH, SET DFXPATCH — exact commands in CONSOLE_STAGEIX.txt), shut down cleanly, boot ISL> START NORECOVERY, and run live verification:

:STREAM JDFXVER.DFXW.SYS

Confirm VERIFY ALL OK 15 and SECCHK 17 OF 17 OK, then complete the short interactive SOMPATCH step for Support Tools Manager diagmond in Section 8 of INSTALL-STAGEIX.md.

One-Command Stage/iX Rollback

Switching back to unpatched BASE anytime

Do not run STAGEMAN> COMMIT so your unpatched BASE archive stays available. With the system clock <= 2027, you can revert online or at ISL> in one command:

:STAGEMAN
STAGEMAN> SET BASE
STAGEMAN> STATUS
STAGEMAN> EXIT
  -- or offline at the console ISL> prompt: --
ISL> STAGEISL
STAGEISL> SET STAGE=BASE
STAGEISL> EXIT
Option 2 · CSLT & Tape

Simple Tape (CSLT) Instructions

Summary of INSTALL-TAPE.md and CONSOLE_TAPE_FULL.txt inside the Tape zip. Have 2 blank write-enabled system tapes ready (Back-Out CSLT & Patched CSLT).

Which Kit File Inside the Tape Zip Should I Use?

kit_b1.std (Real Hardware) vs. kit_b1.tap (Emulators)

  • Real HP 3000 Hardware → use kit_b1.std: Binary-FTP kit_b1.std to KIT.PUB.SYS;REC=-256,1,F,BINARY;CODE=2501;DISC=20000. If B5152AA Store-to-Disk is installed, restore directly with :FILE T=KIT.PUB.SYS;DEV=DISC (saving a third tape) while still cutting physical CSLT reels! Otherwise, write KIT.PUB.SYS onto a physical kit tape on LDEV 7 using freeware TAPECOPY.PUB.SYS;INFO="DT" (never pass kit_b1.tap to TAPECOPY) and write-protect that reel.
  • Virtual Tape Drives (SIMH / QEMU / Devices on Demand) → use kit_b1.tap: Mount kit_b1.tap read-only on LDEV 7.
Steps 1 & 2 · Preflight & Kit Restore

Run JDFXPF first, then restore @.DFXW.SYS

After a verified full system backup, create DFXW.SYS, restore the 4 preflight files from *T, and stream JDFXPF.DFXW.SYS. Proceed only on JDFXPF ALL FIT - GO ON TO STEP 10, then restore @.DFXW.SYS (39 files) and DFXLICEN.PUB.SYS,/opt/.clkfmt,/SYS/.offset;KEEP;SHOW;CREATE=PATH. (If your tape drive is not LDEV 7, edit !SETVAR TAPELDEV in JDFXBAK and JDFXCUT.)

Step 3 · Unpatched Back-Out CSLT (Blank Tape #1)

Cut JDFXBAK and verify at CHECKSLT level 2

Mount Blank Tape #1 write-enabled, cut a complete unpatched System Load Tape of your live system, and verify it before building anything:

:STREAM JDFXBAK.DFXW.SYS
:PRINT SGOUTBAK.DFXW.SYS;PAGE=0
:CHECKSLT.MPEXL.TELESUP   (enter level 2 → confirm 0 errors across all 3 file groups)

Remove, label, and write-protect your Back-Out CSLT tape.

Steps 4 & 5 · Build & Cut Patched CSLT (Blank Tape #2)

Stream JDFXLNK / JDFXAPP / JDFXSTA, then cut JDFXCUT

Stream JDFXLNK, JDFXAPP, and JDFXSTA sequentially in DFXW.SYS. Then mount Blank Tape #2 write-enabled and cut your Patched CSLT (HOLD + TAPE MODE=NOCHANGE leaves your on-disc SYSGEN configuration untouched):

:STREAM JDFXCUT.DFXW.SYS
:PRINT SGOUTCUT.DFXW.SYS;PAGE=0
:CHECKSLT.MPEXL.TELESUP   (enter level 2 → confirm 0 errors across all 3 file groups)

Remove, label, and write-protect your Patched CSLT tape.

Step 6 · ISL> UPDATE, Two Disc Boots & JDFXFIN

Install the 10 core SLT files + 7 standalone utilities

  1. Shut down cleanly (STMSHUT, NSCONTROL STOP, NETCONTROL STOP, SHUTDOWN SYSTEM), boot from the write-protected Patched CSLT tape (Interact with IPL? Y), and enter ISL> UPDATE.
  2. Complete the standard two-boot disc startup: After END of LOAD(update)., boot from your primary disc (ISL> START NORECOVERY). The first boot runs SYSSTART UPDATE processing with LIMIT 1,1 (CIERR 80) — do not log on; press Ctrl-A, enter =SHUTDOWN, and boot ISL> START NORECOVERY a second time.
  3. Log on as MANAGER.SYS,PUB and stream :STREAM JDFXFIN.DFXW.SYS to install the 7 standalone utilities and verify all 17 live files (VERIFY ALL OK 15 + SECCHK 17 OF 17 OK), then apply the interactive diagmond step in INSTALL-TAPE.md §9.

Tape Back-Out: With clock <= 2027, stream :STREAM JDFXFNB.DFXW.SYS (restores the 7 stock utilities), shut down cleanly, and boot your verified Step 3 Back-Out CSLT for ISL> UPDATE + two disc boots.

Permanent Unlock

Ordering a Permanent License

One small ASCII file (DFXLICEN.PUB.SYS) unlocks your machine through 2077.

Send Two Quick Status Outputs to EchoServ

Log on as MANAGER.SYS, run these two read-only commands, and email the output to craig@allegrosupport.com:

:SHOWVAR HPCPUNAME,HPSUSAN
:LINKCONTROL @;STATUS=CONFIGURATION
  • Bound to Factory Default Station Address: Permanent licenses validate HPSUSAN, HPCPUNAME, and your PCI 100BT adapter's factory Default Station Address — so NMMGR software-overridden Current Station Address settings (for SNA, DECnet, or failover) and custom link names continue to work seamlessly. (On legacy non-PCI 900-series DIO/NIO LAN adapters or systems with no configured LAN link, station-address matching is skipped automatically.)
  • Installing your license: Upload the returned file in ASCII mode as DFXLICEN.PUB.SYS (REC=-80,,F,ASCII, no lockword). Full 2028–2077 operation is active immediately.
Reference

What Is Updated, Operator Notes & Checksums

Full details are in RELEASE-NOTES-DATEFIX.md inside both downloads.

The 17 Updated MPE/iX 7.5 Files (Plus STM diagmond)

  • Core OS & Command Interpreter: NL.PUB.SYS (16-bit CALENDAR windowing 1950–2077, leap years 2028..2076, file-label membrane, password aging, spooler SELEQ, clean SHUTDOWN SYSTEM past 2038), START.MPEXL.SYS, STAGEISL.MPEXL.SYS, SL.PUB.SYS (:STREAM scheduling across 2028–2077, CM FMTCALENDAR/DATELINE/CONVERTDATE), CI.PUB.SYS, CATALOG.PUB.SYS, and VERSION.PUB.SYS (C.75.SE Special Edition 2026).
  • Commercial Languages & Shared Runtime (XL.PUB.SYS): Native Mode COBOL II/XL (COB74XL & COB85XL ACCEPT ... FROM DATE/DAY/DAY-OF-WEEK and CURRENT-DATE), Native Mode RPG/XL (UDATE, *YEAR, TIME), plus ALLBASE/SQL, HP Business BASIC/XL, and Transact/iX shared date intrinsics.
  • Backup, Databases, File Transfer & Diagnostics: PA-RISC 1.1 STORE.PUB.SYS & STORECAT.PUB.SYS, TurboIMAGE/XL DBSCHEMA.PUB.SYS & DBRECOV.PUB.SYS, QUERY.PUB.SYS, MSGUTIL.PUB.SYS, KSAMUTIL.PUB.SYS, ARPA FTP.ARPA.SYS & FTPSRVR.ARPA.SYS, and STM /usr/sbin/stm/uut/bin/sys/diagmond (post-2010 startup fix).

Good to Know Before Testing High Dates

  • Hardware clock caution (:SETCLOCK ...;NOW): SETCLOCK ;NOW writes your HP 3000's non-volatile PDC hardware clock. Only run optional 2028 clock checks when no users or production jobs are active, never set production clocks at or past 2038 (POSIX 32-bit time_t tools remain subject to the 2038-01-19 epoch ceiling), and always restore the true current date and time right afterward.
  • Legacy Compatibility Mode COBOL (COBOLII CODE=PROG): Native Mode COB74XL and COB85XL are fixed in Release B1. Legacy CM COBOLII programs linked against CM COBLIB.PUB.SYS compute dates from the raw 7-bit year; recompile with COB74XL/COB85XL or call windowed DATELINE/FMTCALENDAR directly (CM COBLIB is scheduled for the next release).
  • ANSI tape expiration labels: :FILE ...;LABEL= accepts expiration years through 2049; avoid assigning 2028+ ANSI HDR1 tape expiration dates in Release B1 (zero-expiry tapes work cleanly with STORE and RESTORE).

Package & Kit Checksums

FileSizeMD5 / SHA-256
EchoServ-MPEiX75-DateFix-B1-StageiX.zip
Recommended Stage/iX Web Package
372,841 B
(364.1 KB)
MD5: f778a9efcbc17ee6229b25bc42f5d6e8
SHA256: 86086fd42d88171d830ecd48fb5dfb0458100cb4ebe7e390681a450a2f718847
EchoServ-MPEiX75-DateFix-B1-Tape.zip
CSLT & Physical / Virtual Tape Package
723,027 B
(706.1 KB)
MD5: 248e1f9e406e53d6a14467a75f71d8f9
SHA256: 1d9dd1e2cc08f34bfdb7bb800f378e49a2b44742d60c7050173c45e632468830
kit_b1.std (inside both zips, CODE=2501) 1,427,456 B MD5: 5544a1bacd97cbc1c1513fb5101edd95
SHA256: abeb89d971b6fb4c7b1624520304707a8fa405135d7d08298568555f7dfb35fa
kit_b1.tap (inside Tape zip, SIMH .tap) 1,427,456 B MD5: 1c89288ff21f1a2a12e195cbff4e7750
SHA256: 21e03dad8edbec4c9546ca5e0b1df73f8e885dd2892c7043df813612b3c700fc